Telescope voltage tester for trolley buses
Teleskopspannungsprüfer für O-Busse Trolley-Busse bei der Anwendung

Trolley buses TT-OB

Telescope voltage testers up to 1000 V AC / 1500 V DC

1000 V AC / 1500 V DCTelescope up to 10 m

The MultiSafe TT-OB is a telescope voltage tester for quick voltage testing on overhead contact lines of trolley buses.
Its quick and easy-to-use telescope system makes work easier and saves time. The TT-OB is the ideal testing device for on-call duty and fire brigades.

Fully automatic measuring sequences and only one button eliminate operating errors. Its integrated self-test enables quick functional testing of the device on site without further aids. With different sizes and overheadline distances, we offer the ideal test device for every application.

Its 360° visual display system, complemented by LCD display and audible warning, guarantee good perception in all environments.The sealed protective resistors reduce the high voltage to a harmless level. We guarantee the highest safety through surge voltage tests > 100 kV and the unique TST safety module with continuous redundant monitoring.

Branchen Foto O-Busse
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 600 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 1200 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 1100 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 800 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 700 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 700 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 600 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 1200 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 1100 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • display range:
    50 – 1 000 V AC / 50 – 1 500 V DC
  • integrated self-test
  • > 100 kV surge voltage proof
  • response voltage Ut 250 V
    (red / green change)
  • for overheadline distance of 800 mm
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
Telescope voltage tester for trolley buses

1.830,001.980,00

Excl. VAT (in the EU), plus shipping costs

Delivery time: max. 10 weeks (exact delivery date with OC)

Voltage tester:
  • precise display of the voltage 50 – 1 000 V
  • large two-color illuminated display (red / green), for a clear warning of dangerous voltages
  • clear LED indicator for dangerous voltage
  • 360° illuminated band lights up (red / green) in all directions
  • acoustic warning of dangerous voltage
Safety:
  • integrated self-test for quick checking of the protective resistors, connecting cable, display and electronics
  • over 100 kV surge voltage proof
  • highest degree of safety provided by molded protective resistors
Further functions:
  • telescope system for easy and quick testing
  • variable test height up to 6,20 meters
  • for indoor and outdoor use
  • various versions for testing on contact lines with 700 mm distance*
  • easy operation with just one button
  • robust housing
  • IP 65 – waterproof

* other overheadline distances on request

Technical data TT-trolley bus
TT S-OBTT M-OB
Nominal voltage50 - 1 000 V AC
50 - 1 500 V DC
Display range50 - 1 000 V AC
50 - 1 500 V DC
Frequency rangeDC / 15 - 500 Hz
Test height approx. up to6,2 m
Transport length1,35 m1,65 m
Telescopic system6 part4 part
Frequency indicationyes
Overheadline distance600 mm / 700 mm / 800 mm / 1100 mm / 1200 mm

Changeable overheadline distanceyes, through accessory modules
Indicator groupI (optical)
and
III (acustic)
LED indicator red / greenyes
Two-color LCD displayyes
Integrated self-testyes
Power supply6 x 1,5 V AA
Surge voltage strength100 kV
For indoor applicationsyes
For outdoor applicationsyes
For use in moist environments (rain)yes
Degree of protectionIP 65
Art.-no.89357-OB789356-OB7
Product dimensions and weight1350 x 120 x 110 mm

3500 g
1650 x 120 x 110 mm

4000 g
Product packaged dimensions and weight1410 x 200 x 190 mm

6000g
1710 x 200 x 190 mm

5500 g

Download catalog now!

Aufreihung der Spannungsprüfer

Do you still have unanswered questions?

Please feel free to contact us! We will be happy to help you personally and process your request as quickly as possible.

Cookie-Einstellungen
Auf dieser Website werden Cookie verwendet. Diese werden für den Betrieb der Website benötigt oder helfen uns dabei, die Website zu verbessern.
Alle Cookies zulassen
Auswahl speichern
Individuelle Einstellungen
Individuelle Einstellungen
Dies ist eine Übersicht aller Cookies, die auf der Website verwendet werden. Sie haben die Möglichkeit, individuelle Cookie-Einstellungen vorzunehmen. Geben Sie einzelnen Cookies oder ganzen Gruppen Ihre Einwilligung. Essentielle Cookies lassen sich nicht deaktivieren.
Speichern
Abbrechen
Essenziell (1)
Essenzielle Cookies werden für die grundlegende Funktionalität der Website benötigt.
Cookies anzeigen
Statistik (2)
Statistik Cookies tracken den Nutzer und das dazugehörige Surfverhalten um die Nutzererfahrung zu verbessern.
Cookies anzeigen